RDL-2000 Installation Guidelines
70-00144-01-01 Proprietary Redline Communications © 2011 Page 51 of 52 March 9, 2011
5.2.4 Throughput Test
1. On PC #1, go to the Throughput Test screen. Set the address to
192.168.25.20 (PC #2), set the data rate to 10 Mbps, and click the Start
button to begin transmitting data.
2. On PC #2, go to the Throughput Test screen and click the Rx button to start
listening for data. Observe that the Rx counter adjacent to the Rx button
indicates that data is being received and the rate is approximately 10 Mbps.
3. On PC #1, adjust the slider to increase the data rate and observe that PC #2
is correctly receiving at the same rate.
4. Click the End button on both PCs to stop the throughput test.