RDL-2000 Installation Guidelines
70-00144-01-01 Proprietary Redline Communications © 2011 Page 28 of 52 March 9, 2011
The Ethernet cable must be inserted through the mounting plate and grommet
before the RJ-45 connector is installed on outdoor Ethernet cable.
When assembled correctly, the Ethernet port seal will be weather-resistant.
Use the following steps to:
1. Install the Ethernet port weatherproof grommet and clamp onto the cable.
a. Insert the grommet into the grommet clamping plate. The grommet must be
threaded through the metal clamping plate first
. This operation will not be
possible after the Ethernet cable has been inserted through the grommet.
b. Thread the Ethernet cable through the rubber grommet/metal clamping plate
combination (see Figure 17). The large end of the grommet should be
oriented towards the unterminated end of the cable.
Figure 17: Installation - Ethernet Port Cover Plate & Grommet
2. Terminate the cable using the supplied RJ-45 connector. The RDL-2000 Ethernet
port uses a custom pinout for the PoE signals. All Ethernet cables from the
indoor PoE to the outdoor RDL-2000 must
be terminated to match the
specifications in Table 9.
Table 9: Installation - Outdoor Ethernet Cable Termination
RJ-45 Conn. Signal Color Code Identification
1
RX +
White / Orange
2
Rx -
Orange
3
Tx +
White / Green
4 No Connection
5 No Connection
6 Tx - Green
7 +Ve Blue
8
-Ve
Brown
Note: Color codes are provided for convenience only. All signals must match the
connector assignments. Do not
terminate wires to pins 4 an d 5 on the RJ-45
connector.